* feat(#3907): gates report no-input instead of asserting a verdict they never reached The three stdin-reading gates bound 2 to a stdin read error only, with no arm for stdin closed at zero bytes - so empty input flowed into the detector, found nothing, and exited 1, which each module's own comment defines as a negative verdict. An unset PHASE_SECTION made the UI gate assert the phase has no UI. Empty and whitespace-only input now exit NO_INPUT, and a read error exits UNAVAILABLE rather than a locally-invented 2, both resolved through the registry and delivered by terminateNow. The exit code was only half of it: under --json the same input emitted {detected:false}, byte-identical to the fabricated payload #3909 exists to fix, and the blocking coverage gate reads that payload. Empty input now emits the in-tree {skipped:true,reason} form with no detected key at all. teams-status is excluded: it never reads stdin and has no invented 2, so the four-module framing in the issue and ADR is wrong. The dead root bin/lib/ui-safety-gate.cjs is deleted - no installer reference, no workflow invocation, and the live fallback chains are for other modules. Its removal restores the unit tests to the module that actually ships; they had been asserting the stale copy's two-field shape, which is why it drifted unnoticed. * fix(#3907): drive gate tests through the process seam, and make removed-but-needed basename-precise CONTRIBUTING requires every subprocess go through tests/helpers/process-seam.cjs; two of the three gate suites hand-rolled spawnSync while the third, added in the same change, used runNode correctly for the identical injection case. Converted the blocks this change added, leaving pre-existing ones alone. Deleting one of two files sharing a basename made lint-removed-but-needed report 14 references that were all to the surviving canonical module - the false-positive class its own docstring names. It now matches on the deleted file's full path when a surviving file shares its basename, which is more precise rather than weaker: a genuine full-path reference still fails, and behaviour is unchanged when no basename collides. It immediately caught a docstring on this branch that spelled the deleted path. * test(#3907): update the one existing assertion that pinned the old empty-stdin verdict A pre-existing test asserted exit 1 on empty stdin - the defect this phase removes - and was missed because the change added new blocks without auditing existing ones pinning the old contract. Audited the rest: the other three status-1 assertions in that file all feed real input and are the genuine-negative controls that must keep returning 1, so exactly one was stale. The retired 2 is gone from the describe's contract comment too. * chore(#3907): backfill changeset pr number --------- Co-authored-by: sim <sim@local>
This commit is contained in:
@@ -20,17 +20,19 @@
|
||||
* tunable (config + the `terms` parameter) so teams can widen it.
|
||||
* - FENCED CODE BLOCKS ARE STRIPPED first (via the markdown-sectionizer seam)
|
||||
* so a trigger term that appears only inside a code snippet does not fire.
|
||||
* - Mirrors ui-safety-gate.cts: a pure function + a STDIN-reading CLI whose
|
||||
* exit codes mirror grep (0 = signal found, 1 = none, 2 = usage error).
|
||||
* - Mirrors ui-safety-gate.cts: a pure function + a STDIN-reading CLI.
|
||||
*
|
||||
* Public API:
|
||||
* detectAssumptionDelta(text, terms?) -> { detected, signals, terms }
|
||||
* DEFAULT_ASSUMPTION_DELTA_TERMS
|
||||
*
|
||||
* CLI:
|
||||
* CLI (ADR-3889 Phase 3, #3907):
|
||||
* echo "$PHASE_SECTION" | node gsd-core/bin/lib/assumption-delta.cjs [--json]
|
||||
* exit 0 = signal detected, 1 = none, 2 = startup error
|
||||
* --json additionally prints the typed IR on stdout
|
||||
* exit 0 = signal detected, 1 = none (real input, examined, no signal),
|
||||
* NO_INPUT (registry, src/cli-exit.cts) = stdin empty/whitespace-only,
|
||||
* UNAVAILABLE (registry) = stdin read failed
|
||||
* --json additionally prints the typed IR on stdout (unchanged for 0/1);
|
||||
* NO_INPUT/UNAVAILABLE print {skipped:true, reason:"no_input"|"stdin_error"}
|
||||
*/
|
||||
|
||||
import { stripFencedCode } from './markdown-sectionizer.cjs';
|
||||
@@ -214,11 +216,25 @@ export function detectAssumptionDelta(
|
||||
// ── CLI entry point ──────────────────────────────────────────────────────────
|
||||
// Reads phase-section text from STDIN (not argv) to avoid OS ARG_MAX limits.
|
||||
// Invoked by workflow bash as: echo "$PHASE_SECTION" | node .../assumption-delta.cjs [--json]
|
||||
// Exit 0 = signal detected, 1 = none, 2 = startup error. Mirrors ui-safety-gate.
|
||||
//
|
||||
// Exit codes (ADR-3889 Phase 3, #3907): 0 = signal detected, 1 = none (real
|
||||
// input, examined, no signal), NO_INPUT (registry — src/cli-exit.cts) = stdin
|
||||
// empty/whitespace-only, UNAVAILABLE (registry) = stdin read failed. The prior
|
||||
// single "2 = startup error" arm let empty input flow into the detector and
|
||||
// exit 1 — an unexamined input reported as an authoritative negative. Under
|
||||
// --json, NO_INPUT/UNAVAILABLE emit `{skipped:true, reason:"no_input"|
|
||||
// "stdin_error"}` — no `detected` key, so a stale `detected:false` can never
|
||||
// sit beside `skipped:true`; the detected/no-signal `--json` payloads are
|
||||
// byte-identical to before. Terminates via terminateNow (write-then-terminate,
|
||||
// total by construction), not raw process.exit — these exits fire from inside
|
||||
// a stdin event handler. Mirrors ui-safety-gate.cjs / api-coverage.cjs.
|
||||
|
||||
if (require.main === module) {
|
||||
const argv = process.argv.slice(2);
|
||||
const wantJson = argv.includes('--json');
|
||||
|
||||
// eslint-disable-next-line @typescript-eslint/no-require-imports
|
||||
const cliExit = require('./cli-exit.cjs') as { terminateNow: (outcome: string, payload: unknown) => never };
|
||||
// --terms <csv>: config-tunable vocabulary override. Replaces the
|
||||
// pluralization cues (the primary trigger); optional/chosen keep defaults.
|
||||
// An EMPTY value ("") or a flag-shaped value restores the curated defaults
|
||||
@@ -241,15 +257,19 @@ if (require.main === module) {
|
||||
|
||||
process.stdin.on('end', () => {
|
||||
const input = chunks.join('');
|
||||
const result = detectAssumptionDelta(input, termsOverride);
|
||||
if (wantJson) {
|
||||
process.stdout.write(JSON.stringify(result) + '\n');
|
||||
// Whitespace-only counts as empty (ADR-3889 §1's NO_INPUT: "zero units
|
||||
// were in scope, and that emptiness is known to be genuine"). Real input
|
||||
// — including a lone NUL byte, which .trim() does not strip — always
|
||||
// falls through to the detector.
|
||||
if (input.trim().length === 0) {
|
||||
cliExit.terminateNow('NO_INPUT', wantJson ? { skipped: true, reason: 'no_input' } : undefined);
|
||||
}
|
||||
process.exit(result.detected ? 0 : 1);
|
||||
const result = detectAssumptionDelta(input, termsOverride);
|
||||
cliExit.terminateNow(result.detected ? 'PASS' : 'FAIL', wantJson ? result : undefined);
|
||||
});
|
||||
|
||||
process.stdin.on('error', (err: Error) => {
|
||||
process.stderr.write(`ERROR: assumption-delta.cjs stdin read failed: ${err.message}\n`);
|
||||
process.exit(2);
|
||||
cliExit.terminateNow('UNAVAILABLE', wantJson ? { skipped: true, reason: 'stdin_error' } : undefined);
|
||||
});
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user