* enhance(#3911): give hooks an exit seam that needs no build ADR-3889 Phase 7 foundation. The 19 shipped enforcement hooks hold 91 of the epic's 128 terminators and cannot reach `terminateNow` today. The obvious route — requiring `gsd-core/bin/lib/cli-exit.cjs`, as gsd-agent-isolation-guard.js already does for two other modules — is rejected. That precedent carries its own warning (#3582): those files are tsc output, gitignored and absent on a raw plugin-marketplace or git-clone install, so the hook must first call ensureRuntimeBuild() to self-heal. Making the module a hook needs IN ORDER TO TERMINATE depend on a build inverts the dependency, and its failure mode is precisely the fail-open this phase exists to remove: a guard that cannot terminate cannot deny. `lint-hooks-runtime-build-seam` already encodes that concern, and Design B would have had to add an ensureRuntimeBuild() call to all 19 hooks to satisfy it. So `hooks/lib/` becomes a third emit location for cli-exit and a fifth for the registry, preserving the invariant `src/cli-exit.cts`'s own header states: it imports nothing but node:fs and its sibling registry, and the generator dual-emits that sibling alongside each copy so a relative require resolves next to whichever copy loaded it. Shipping needed no change — build-hooks.js already declares HOOKS_SUBDIRS_TO_COPY = ['lib']. Proven, not asserted: the two files are copied into an otherwise-empty tmpdir and a child process requires them and terminates — PASS exits 0, HOOK_DENY exits 2 with the payload on both stdout and stderr. That test fails the moment the hooks copy gains a require reaching outside hooks/lib/. Also fixed inline: the registry's fifth target let any `--write` test overwrite the real committed hooks/lib/exit-code-registry.js, because the test helper derived only three of the other output paths. It now redirects all five, and a regression test asserts every committed artifact is byte-identical after a redirected write. Install-tree goldens pick up the two new shipped paths across 11 runtimes — insertions only, no removals. lint:ci was green while they were stale, so this was found by regenerating rather than by a gate. Verification runs on the remote runner. Refs #3911 * enhance(#3911): declare a crash policy, and migrate the write guard Adds `hooks/lib/hook-exit.js` — the hook-facing vocabulary over `terminateNow`, hand-written because the cli-exit copy beside it is generated: allow(payload) exit 0 deny(payload, stderr?) exit 2 crash(onCrash, payload) whichever the hook DECLARED `crash()` takes the policy as a required argument with no default, which is the whole mechanism: fail-open by accident stops being expressible. A hook must name ALLOW or DENY at the call site, and an unrecognized value terminates INTERNAL rather than guessing. Fail-open stays legal; fail-open by omission does not. `gsd-write-guard.js` is the first hook migrated, all 12 sites, and it exposed a gap in the seam. `terminateNow`'s doc comment justified its fd-2 write by citing this hook's `emitBlock` — but modeled it as sending the same bytes to both streams, when `emitBlock` actually sends full JSON to stdout and only the bare `reason` string to stderr, because Kimi's hook bus feeds stderr verbatim back to the model. Migrating as written would have turned a readable sentence into a JSON blob for Kimi-backed agents. #3911 requires both "all 19 hooks terminate through terminateNow" and "no hook's effective default changes". Those are jointly satisfiable only by teaching the seam to carry a distinct stderr payload, so `terminateNow` gains an optional third argument: omitted, behavior is byte-for-byte what it was; a string is written raw, which is exactly the Kimi case. The doc comment's inaccurate claim about emitBlock is corrected in place. Proven rather than asserted: the pre-migration file is reconstructed from HEAD and driven with the same catastrophic-shrink payload as the migrated one — exit code, stdout and stderr all byte-identical. Verification runs on the remote runner. Refs #3911 * enhance(#3911): all 19 hooks terminate through the seam Migrates the remaining 18 enforcement hooks onto allow/deny/crash. An AST walk now reports zero `process.exit(` call sites across every `hooks/*.js` — down from the 91 the census measured. Each hook with an outer catch declares its policy once, at module top, with the reason that policy is right for that specific guard: a read guard that cannot scan must not block the read; a statusline that renders every prompt must degrade rather than crash; an injection scanner must not retroactively block a result already returned. Those sentences are the deliverable — they are what turns fail-open-by-accident into fail-open-on-purpose. No hook's effective default changed. Wiring exposed two defects, both fixed here rather than noted. A SECOND stdout/stderr-splitting site turned up in `gsd-workflow-guard.js`'s `emitForceAddBlock`, matching the pattern already known from the write guard — full JSON to stdout, bare reason to stderr for the Kimi bus. It uses the `stderrPayload` argument added in the previous commit, which is now carrying its second real caller rather than one special case. More seriously, `terminateNow` emitted both streams inside ONE try, so a payload that failed to serialize aborted before the stderr write ever ran. The two windsurf guards write nothing to stdout on a block and only a reason string to stderr, so `deny(undefined, reason)` exited 2 with EMPTY stderr — a deny that silently loses its reason, which is the exact "fails with success" class this epic exists to close. The streams are now emitted independently, each with its own guard, and `undefined` means "nothing to write for this stream" rather than an error. Regression tests inject a throwing write on one fd and assert the other still receives its payload; they fail against the single-try version. Byte-identity was proven per hook, not assumed: each pre-change file is reconstructed from HEAD and driven side by side with the migrated one across its normal path, its deny path, malformed stdin and empty stdin — exit code, stdout and stderr compared. Verification runs on the remote runner. Refs #3911 * enhance(#3911): harden the three shell hooks, and pin every hook's policy `gsd-phase-boundary.sh`, `gsd-session-state.sh` and `gsd-validate-commit.sh` gain `set -euo pipefail`. The expected hazard did not materialize, and that is worth recording: every intentionally-non-zero command in all three is already the condition of an `if`/`elif`, which `set -e` never fires on, and none of them reads a possibly-unset variable or pipes through a grep that may legitimately match nothing. No `|| true` guards were needed. Each hook was still checked command-by-command before the flags went in rather than after. Twenty-one before/after cases across the three hooks — disabled and enabled, planning and non-planning, missing STATE.md, malformed JSON, the Kimi payload shape, quoted and unquoted `-m`, valid and over-long Conventional Commits — all match on exit code, stdout and stderr. The hardening is shown to actually fire, not merely added: with a stubbed `node` that fails at the JSON-emit step, phase-boundary and session-state go from silently exiting 0 with empty stdout to failing visibly with the error surfaced. No such case could be constructed for `gsd-validate-commit.sh`, whose every statement already sits inside an if-condition — recorded as unproven rather than claimed. `tests/hooks-crash-policy.test.cjs` adds the per-hook coverage the issue asks for, table-driven over all 19 hooks rather than 76 hand-written cases: normal allow, deny where a deny path exists, crash-honors-the-declared-policy, and an unclosed-stdin case — the one `process.exitCode` structurally cannot serve. The deny assertions encode each hook's ACTUAL stream split rather than a uniform shape, since four of the six deliberately differ. A drift guard enumerates `hooks/*.js` and fails if a terminating hook is ever added without a row. Writing those tests surfaced two hooks that emit a block decision in their JSON body and exit 0. Both were checked rather than assumed, and neither is a fails-with-success: `gsd-read-injection-scanner.js` is PostToolUse, where the tool has already run and exit 2 has no meaning, and `gsd-cursor-subagent-start.js` follows Cursor's JSON-body protocol. They are deliberately left alone — a mechanical sweep to `deny()` would have broken exactly these two. Verification runs on the remote runner. Refs #3911 * fix(#3838): the commit validator says when it could not validate #3911 claims to subsume #3838. Measurement said otherwise, so this closes it for real rather than by assertion. `set -euo pipefail`, added earlier on this branch, does NOT fix #3838: bash exempts a command used as an `if` condition from `set -e`, and all three of the hook's swallow-and-pass sites are exactly that shape. Verified against the hardened hook with a node shim that fails only the classifier call — a non-conforming commit still exited 0 with empty stdout AND empty stderr, indistinguishable from "your commit conforms". That is the defect verbatim. All three sites named in #3838 now capture the real exit status instead of consuming it as a condition, and each distinguishes its genuine negative from "could not run": - the classifier: 0 = is a git commit, 1 = genuinely not one, anything else = could not classify. Its `node -e` now wraps the require and the call in try/catch and exits 3 on a throw, so a broken require chain can never be mistaken for `isGitSubcommand` legitimately returning false — which is the arm that matters, since `token-scanner.cjs` is a gitignored build artifact and a fresh checkout lands there. - the opt-in config read and the JSON command extraction get the same treatment. On "could not run" the hook emits a diagnostic to stderr naming which check failed and why, then exits 0. The issue confirms this is safe — it is a PreToolUse hook, so stderr does not disturb the JSON protocol — and ranks it the smallest sufficient fix. The gate still fails open, but it can no longer do so silently, which is the whole complaint: a validator that disables itself quietly costs more than one that is absent, because it is trusted. Both controls are unchanged and pinned by tests: a conforming commit still passes silently, a non-conforming one still exits 2 with its existing block payload. The defect test asserts stderr is non-empty and names the failure; it fails against the pre-fix hook. Verification runs on the remote runner. Refs #3911, #3838 * docs(#3911): document the hook crash-policy contract Reference and Explanation via a new docs/features fragment (FEATURES.md is generated from it), INVENTORY rows for the three new hooks/lib files, and an ARCHITECTURE note on the hooks section. How-To: docs/how-to/declare-a-hook-crash-policy.md, indexed from docs/README.md — a hook author now has to choose and declare a crash policy, which is more than one step and crosses into which harness protocol their hook speaks. It covers allow/deny/crash, writing an ON_CRASH reason that is actually useful, when a deny needs a distinct stderr payload, the two hooks whose harness reads a JSON-body decision and must NOT use deny(), and what to do when a check cannot run at all — with #3838 as the worked example. Refs #3911 * test(#3911): prove the seam actually ships, and stop hand-rolling temp cleanup Two review findings. The acceptance criterion 'hooks/dist/** stays in parity via the build seam (lint:hooks-runtime-build-seam)' was misstated and unmet: that lint checks something else — that a hook requiring a compiled gsd-core/bin/lib module also calls ensureRuntimeBuild(). Nothing exercised that the three new hooks/lib files reach hooks/dist/lib at all. That gap is not theoretical: #770 is a recorded ship-blocking bug where a new hook never shipped because a copy list missed it. The suite now builds dist through the repo's own ensureBuiltHooks(), byte-compares each shipped copy against its source, and spawns a child that requires the SHIPPED dist copy and denies — which is what catches a copy that exists but cannot resolve its sibling registry. gsd-validate-commit.sh hand-duplicated mktemp/run/rm three times; one idempotent trap on EXIT replaces them, guarded so cleanup cannot alter the exit status. Behavior-neutral across five cases, with temp-file counts taken before and after each run. Refs #3911 * fix(#3911): stage transitive hook lib requires, not just one level The remote run returned 7 failures across 3 real causes. The important one is a PRODUCTION bug this phase exposed rather than caused. `writeCursorHooksJson` scanned each hook script for `./lib/X` requires exactly one level deep and never re-scanned the lib files it staged for their own sibling requires. Nothing had a transitive lib dependency before, so the gap was invisible. Adding hook-exit.js -> cli-exit.js -> exit-code-registry.js made real Cursor installs ship a bundle that dies at require time with MODULE_NOT_FOUND. It now walks to a fixed point, and a real installed Cursor hook runs to completion. The staging harness in shared-hooks-dir-resolution hand-copied its fixture, so the injection scanner crashed at require time and its exit-1 was being read as a policy decision. Migrated to copyScriptWithDeps, which walks the require graph — the repo's recorded rule for this class, since adding another copyFileSync keeps it alive for the next person. The missing-lib-source test in cursor-hook-workspace-roots hardcoded which lib file it expected to be named in the abort message; the same throw now fires for a different file first. Its assertion is unchanged in substance — staging still must abort rather than ship a broken hook — only the name is no longer pinned. The last one was my own test asserting an uppercase reason code. Measured against origin/next: the pre-change hook emits the same lowercase 'config_unreadable', so the test was wrong, not the migration. Corrected to the real value rather than making the code match the test. Verification runs on the remote runner. Refs #3911 * chore(#3911): regenerate the cursor install-tree golden The staging fix means a Cursor install now correctly carries the two transitive lib files it was silently missing. Additive only — no path was removed. The golden diff is the evidence the packaging defect was real. Refs #3911 * chore(#3911): backfill the changeset PR number Refs #3911 * fix(#3911): a git probe that timed out is not a negative A macOS CI lane failed three deny cases at 2084ms, 2112ms and 2177ms — just past the 2000ms budget these hooks give their git probes. The three that passed took 72ms, 595ms and 651ms. Under shard contention `git rev-parse` overruns, the hook reads the non-zero result as "not a git repo", and allows with exit 0 and empty stdout AND empty stderr. Under load, the guards silently stop guarding. That is ADR-3889's thesis exactly, sitting inside the security hooks this phase is about. The repo had already recognized the class in one place — gsd-cursor-subagent-start.js fail-closed-denies on `git_timed_out` (#3045) — but nowhere else. `hooks/lib/git-probe.js` classifies a probe's outcome, distinguishing a real non-zero exit from ETIMEDOUT, a signal kill, and a spawn failure, rather than folding all four into `status !== 0`. Three guards route their eight git probes through it. The resolution is the same shape #3838 took, and the same one that issue endorsed as smallest-sufficient: fail open, but loudly. **No exit code changes on any path** — a developer on a loaded machine is still not blocked, which keeps #3911's declaration-pass contract intact for exit codes. What changes is that the hook now says on stderr which probe could not answer, instead of presenting silence as a clean verdict. Scope was checked across every hooks/*.js, not just the three that failed: gsd-agent-isolation-guard spawns no git; gsd-statusline's two probes gate only a cosmetic display segment, not an allow/deny decision, and are left alone. The C2 deny assertion was a real-race test — it demanded exit 2 while a slow git legitimately yields 0. It now requires the hook to either deny, or allow with a diagnostic naming the probe that could not run; a silent allow still fails, so the assertion is not vacuous. A deterministic regression stubs git on PATH to sleep past the budget rather than waiting for load to reproduce it. Verification runs on the remote runner. Refs #3911 * test(#3911): a PATH shim cannot intercept the hooks' git spawn on Windows The deterministic timeout regression stubbed git on PATH and asserted the guard reports rather than silently allows. It passes on Linux and macOS and failed on Windows in 83ms and 176ms — the stub was never invoked at all. Mechanism: the hooks call spawnSync('git', args) with no shell:true, so on Windows CreateProcess resolves git.exe only and never a PATH .cmd shim. The git.cmd branch could not have worked and is removed rather than left implying a Windows path that does. Adding shell:true to the hooks to serve a test would change product behavior and widen an injection surface, so the case is skipped on win32 only, with the mechanism written into the skip reason so a future reader does not 'fix' it that way. Linux and macOS keep the coverage, and macOS is where the underlying fail-open was actually caught. Refs #3911 --------- Co-authored-by: sim <sim@local>
535 lines
28 KiB
JavaScript
535 lines
28 KiB
JavaScript
#!/usr/bin/env node
|
|
// gsd-hook-version: {{GSD_VERSION}}
|
|
// GSD Agent Isolation Dispatch Guard — PreToolUse hook (#3045)
|
|
//
|
|
// Problem: `gsd-core/workflows/execute-phase/steps/executor-isolation-dispatch.md`
|
|
// resolves the project's dispatch isolation correctly
|
|
// (`gsd_run query dispatch-isolation --raw`), but DELIVERY of that value into
|
|
// the model-authored `Agent(subagent_type="gsd-executor", ...)` call is a
|
|
// prose instruction ("substitute $HARNESS_FLAG's value ... on Claude Code it
|
|
// is literally isolation=\"worktree\""). Nothing verifies the model actually
|
|
// copied it. When it is omitted, the executor runs and commits directly in
|
|
// the user's PRIMARY checkout instead of an isolated worktree, with no
|
|
// consent and no warning.
|
|
//
|
|
// A prose backstop cannot fix a prose defect — it is the same class of
|
|
// artifact the model may equally skip. This hook enforces the invariant at
|
|
// the tooling layer instead: HARD-BLOCKING.
|
|
//
|
|
// Applicability (must positively determine all three to act — otherwise
|
|
// inert):
|
|
// 1. this is a GSD project (`.planning/config.json` exists under cwd),
|
|
// 2. the project's resolved dispatch isolation is `harness-worktree`,
|
|
// 3. the dispatch target is an executor (`subagent_type === "gsd-executor"`;
|
|
// no other executor-shaped subagent type exists in agents/ today).
|
|
//
|
|
// Fail-closed exception (#3050 lesson: a guard that cannot verify must not
|
|
// answer "safe"): if the project IS a GSD project but the hook cannot read
|
|
// or resolve its dispatch-isolation configuration, it DENIES rather than
|
|
// defaulting to the "safe-looking" none/allow value that
|
|
// `gsd-core/bin/gsd-tools.cjs`'s own `routeDispatchIsolation` degrades to on
|
|
// error. That existing query is fail-OPEN by design (sequential execution
|
|
// is always safe for the SCHEDULER); this guard's job is the opposite
|
|
// invariant (never dispatch unisolated when isolation was promised), so it
|
|
// cannot reuse that fail-open default and instead resolves isolation
|
|
// itself, distinguishing "resolved cleanly" from "could not resolve".
|
|
//
|
|
// Isolation resolution (#3045 BLOCKER fix, see hooks/lib/isolation-sentinel.js):
|
|
// prefers the workflow's own PERSISTED per-dispatch decision (a sentinel
|
|
// `record-dispatch-isolation` writes after `executor-isolation-dispatch.md`
|
|
// resolves ISOLATION in shell, applying workflow.use_worktrees, the #2474
|
|
// per-plan submodule degrade, and the #683/#3060 base-check auto-degrade)
|
|
// over re-deriving a host CAPABILITY from the registry. A fresh sentinel is
|
|
// authoritative — `none`/`orchestrator-worktree` ALLOW immediately
|
|
// (sequential/orchestrator-managed dispatch is legitimate, not a bug); an
|
|
// absent/stale sentinel falls back to a conservative registry+config check
|
|
// (GSD_RUNTIME env > .planning/config.json `runtime` > the per-install
|
|
// `.gsd-runtime` marker, #3566 — no confident signal degrades to inert rather
|
|
// than guessing 'claude', see resolveRegistryIsolation)
|
|
// gated additionally by `workflow.use_worktrees` — read directly, in-process,
|
|
// no subprocess spawn.
|
|
//
|
|
// Triggers on: Agent/Task tool calls with subagent_type === "gsd-executor"
|
|
// (both names accepted — #3045 MAJOR 1: only Agent was previously matched,
|
|
// silently inert on any host/version whose subagent tool is named Task).
|
|
// Action: BLOCK (exit 2) when isolation should be enforced and is not
|
|
// No-op: any tool other than Agent/Task, non-executor targets, GSD projects
|
|
// whose resolved isolation is not harness-worktree, non-GSD projects,
|
|
// malformed payloads, or a dispatch that already carries the correct
|
|
// isolation parameter.
|
|
|
|
'use strict';
|
|
|
|
const fs = require('fs');
|
|
const path = require('path');
|
|
const os = require('os');
|
|
const { readSentinel, VALID_ISOLATION, extractDispatchIdentifiers, sentinelAppliesToDispatch } = require('./lib/isolation-sentinel.js');
|
|
const { REASON_CODE } = require('./lib/isolation-deny-reason.js');
|
|
const { HOOK_ON_CRASH, allow, deny, crash } = require('./lib/hook-exit.js');
|
|
|
|
// Required at module top, alongside the other ./lib requires — NOT behind
|
|
// ensureRuntimeBuild() below. Terminating on a parse/timeout failure must
|
|
// never depend on the gitignored build artifacts this hook self-heals for
|
|
// its own registry lookups (#3911).
|
|
//
|
|
// This guard's outer catch (main(), below) has always exited 0 (fail open):
|
|
// that outer catch only covers payload PARSING failing before applicability
|
|
// could even be determined (malformed stdin JSON, etc.) — the guard's real
|
|
// fail-closed logic (a GSD project whose dispatch-isolation configuration
|
|
// cannot be verified) is handled separately, inside evaluateDispatch/
|
|
// resolveIsolationState, and already returns a 'block' decision through the
|
|
// normal exit-2 path rather than through this catch. So an unparseable
|
|
// payload has nothing to enforce; allowing it preserves today's behavior
|
|
// exactly.
|
|
const ON_CRASH = HOOK_ON_CRASH.ALLOW;
|
|
// #3582: gsd-core/bin/lib/*.cjs (runtime-name-policy.cjs, capability-registry.cjs
|
|
// below) are tsc build artifacts (ADR-457), gitignored and absent on a raw
|
|
// plugin-marketplace / git-clone install that never ran `npm run build:lib`.
|
|
// Self-heal before the first such require (resolveRegistryIsolation, below) —
|
|
// see ensureRuntimeBuild's own header for the full rationale. This module
|
|
// itself (gsd-core/bin/ensure-runtime-build.cjs) depends on nothing under
|
|
// ./lib, so requiring it here is always safe.
|
|
const { ensureRuntimeBuild, RuntimeBuildError } = require('../gsd-core/bin/ensure-runtime-build.cjs');
|
|
|
|
// No other executor-shaped subagent_type exists in agents/ today
|
|
// (verified: only agents/gsd-executor.md). A Set, not a bare string compare,
|
|
// so a future sibling executor role can be added here without touching the
|
|
// matching logic below.
|
|
const EXECUTOR_SUBAGENT_TYPES = new Set(['gsd-executor']);
|
|
|
|
/**
|
|
* Parse a registry `harnessIsolationFlag` of the shape `key="value"` (the
|
|
* only shape an `Agent()` tool_input kwarg can express) into its parameter
|
|
* name and expected value. Bare CLI-flag shapes (e.g. a hypothetical
|
|
* `--worktree`) have no tool_input kwarg equivalent and are not checkable
|
|
* here — this hook is scoped to the Claude Code `Agent` tool's keyword-arg
|
|
* dispatch surface.
|
|
*/
|
|
function parseHarnessFlag(flag) {
|
|
if (typeof flag !== 'string') return null;
|
|
const m = /^([A-Za-z_][\w-]*)="([^"]*)"$/.exec(flag);
|
|
if (!m) return null;
|
|
return { param: m[1], value: m[2] };
|
|
}
|
|
|
|
// ─── #3897 rung 2: per-install runtime marker, single canonical owner ────────
|
|
// bin/install.js writes `<install>/gsd-core/.gsd-runtime` for EVERY runtime
|
|
// install (#2297), co-located with VERSION. Unlike `~/.gsd/defaults.json` —
|
|
// which is host-wide and names whichever runtime's install ran LAST, the exact
|
|
// leakage #2840's config.cjs change exists to prevent — the marker describes
|
|
// THIS install, which is the property runtime identity needs on a machine
|
|
// with 2+ runtimes. Previously this hook held its own private reader/cache
|
|
// (one of four #3897 found); it now delegates to the single canonical owner,
|
|
// `src/runtime-slash.cts` (compiled to gsd-core/bin/lib/runtime-slash.cjs),
|
|
// reached through `ensureRuntimeBuild()` like every other compiled-lib require
|
|
// in this file (`scripts/lint-hooks-runtime-build-seam.cjs`).
|
|
function readInstallRuntimeMarker() {
|
|
try {
|
|
ensureRuntimeBuild();
|
|
const runtimeSlash = require('../gsd-core/bin/lib/runtime-slash.cjs');
|
|
return runtimeSlash.readInstallRuntimeMarker();
|
|
} catch {
|
|
// Unbuilt runtime library, or any other failure reaching the canonical
|
|
// owner — "no signal from this rung" (N4), never a resolution failure.
|
|
return null;
|
|
}
|
|
}
|
|
|
|
// Test seam for the marker rung — forwards to the canonical owner's seam so
|
|
// this hook and runtime-slash.cjs always share one cache (#3897 rung 2).
|
|
function _setInstallRuntimeMarkerForTests(value) {
|
|
try {
|
|
ensureRuntimeBuild();
|
|
const runtimeSlash = require('../gsd-core/bin/lib/runtime-slash.cjs');
|
|
runtimeSlash._setInstallRuntimeMarkerForTests(value);
|
|
} catch {
|
|
// Test-only seam; an unbuilt library here means the test itself will fail
|
|
// downstream, which is a louder and more actionable signal than throwing here.
|
|
}
|
|
}
|
|
|
|
/**
|
|
* Resolve this project's declared `runtime` identity WITHOUT defaulting to
|
|
* 'claude' when no explicit signal exists (#3045 MAJOR 2).
|
|
*
|
|
* `gsd-core/templates/config.json` — the actual scaffold used to write every
|
|
* new project's config.json — ships with NO `runtime` key, so "no signal"
|
|
* is the COMMON case, not a corner case. Previously this resolution silently
|
|
* defaulted to 'claude' in that case, which meant every non-Claude runtime
|
|
* that also installs this hook (any `hostIntegration.hooksSurface ===
|
|
* 'settings-json'` runtime, not only Claude) had Claude's
|
|
* `harnessIsolationFlag` ("isolation=\"worktree\"") demanded on its Agent()
|
|
* -equivalent dispatch — a kwarg that runtime's own tool never accepts.
|
|
*
|
|
* Returns `{ runtimeId, confident }`. `confident` is true only when an
|
|
* explicit signal exists (GSD_RUNTIME env override, a `runtime` key literally
|
|
* present in config.json, the per-install `.gsd-runtime` marker, or a
|
|
* `runtime` persisted to `~/.gsd/defaults.json` by the installer — see
|
|
* below); false means "cannot determine" and callers must NOT silently
|
|
* substitute 'claude' — see resolveRegistryIsolation.
|
|
*
|
|
* #3045 BLOCKER 2 fix: precedence is GSD_RUNTIME env > config.json `runtime`
|
|
* key > `~/.gsd/defaults.json` `runtime`. The first two are unchanged; the
|
|
* third is NEW — `bin/install.js`'s `writeNonClaudeDefaults` already persists
|
|
* the installed runtime to `~/.gsd/defaults.json` for every non-Claude
|
|
* runtime install (`defaults.runtime = runtime`, #2395), so this is real,
|
|
* already-shipping data, not a new write. Before this fix, "no signal" was
|
|
* the COMMON case for any project whose config.json was scaffolded from
|
|
* `gsd-core/templates/config.json` (which ships with NO `runtime` key) and
|
|
* whose session had no `GSD_RUNTIME` override — i.e. nearly every non-Claude
|
|
* install, since Claude installs never reach `writeNonClaudeDefaults` at all
|
|
* (`nativeModelAliases` short-circuits it) and therefore correctly still rely
|
|
* on config.json/env. Reading the installer's own persisted signal makes
|
|
* "confident" the common case instead.
|
|
*
|
|
* #3566: the per-install `.gsd-runtime` marker now sits BETWEEN config.json
|
|
* and defaults.json. defaults.json is host-wide and names whichever runtime
|
|
* installed LAST — on a 2-runtime machine that confidently resolves the WRONG
|
|
* runtime (a Codex install's `runtime:"codex"` leaking into Claude projects),
|
|
* and when the wrong runtime declares no harnessIsolationFlag the guard goes
|
|
* silently inert. The marker describes THIS install (written for every
|
|
* runtime since #2297), which is the source #2840's config.cjs change names
|
|
* as correct. defaults.json stays as the final rung so single-runtime default
|
|
* installs and pre-#2297 installs (no marker on disk) keep the #3045
|
|
* BLOCKER 2 behavior.
|
|
*/
|
|
function resolveRuntimeIdentity(cwd, configPath, resolveRuntimeNameFromCandidates) {
|
|
const envRuntime = resolveRuntimeNameFromCandidates(process.env.GSD_RUNTIME);
|
|
if (envRuntime) return { runtimeId: envRuntime, confident: true };
|
|
|
|
// A throw here (corrupt JSON, EISDIR, permission error) propagates to the
|
|
// caller's catch as a resolution failure — this function only decides
|
|
// "confident vs not", never resolution failure.
|
|
const raw = fs.readFileSync(configPath, 'utf-8');
|
|
const parsed = JSON.parse(raw);
|
|
if (parsed && typeof parsed === 'object' && 'runtime' in parsed) {
|
|
const configRuntime = resolveRuntimeNameFromCandidates(parsed.runtime);
|
|
if (configRuntime) return { runtimeId: configRuntime, confident: true };
|
|
}
|
|
|
|
// #3566: the per-install marker, above the host-wide defaults — see the
|
|
// block comment on readInstallRuntimeMarker. An empty/whitespace-only file
|
|
// or an unknown value degrades exactly like the other rungs (no signal /
|
|
// future-runtime tolerance via resolveRuntimeNameFromCandidates).
|
|
const markerRuntime = resolveRuntimeNameFromCandidates(readInstallRuntimeMarker());
|
|
if (markerRuntime) return { runtimeId: markerRuntime, confident: true };
|
|
|
|
// #3045 BLOCKER 2: fall back to the installer-persisted default. Read
|
|
// defensively — an absent/corrupt/non-object defaults.json is "no signal",
|
|
// never a resolution failure (this function only ever throws for the
|
|
// config.json read above, which the caller's catch already handles).
|
|
try {
|
|
const defaultsPath = path.join(os.homedir(), '.gsd', 'defaults.json');
|
|
const defaultsRaw = fs.readFileSync(defaultsPath, 'utf-8');
|
|
const defaultsParsed = JSON.parse(defaultsRaw);
|
|
if (defaultsParsed && typeof defaultsParsed === 'object' && 'runtime' in defaultsParsed) {
|
|
const defaultsRuntime = resolveRuntimeNameFromCandidates(defaultsParsed.runtime);
|
|
if (defaultsRuntime) return { runtimeId: defaultsRuntime, confident: true };
|
|
}
|
|
} catch {
|
|
// Absent or unreadable ~/.gsd/defaults.json — no signal, fall through.
|
|
}
|
|
|
|
return { runtimeId: null, confident: false };
|
|
}
|
|
|
|
/**
|
|
* Resolve the registry-declared `harnessIsolationFlag` descriptor for
|
|
* `runtimeId` — pure host-CAPABILITY lookup, used both when the sentinel
|
|
* confirms harness-worktree but omitted the flag, and by the conservative
|
|
* fallback path. Returns `null` when the host declares no usable flag.
|
|
*/
|
|
function resolveHarnessFlag(runtimeId, runtimes) {
|
|
const runtimeEntry = runtimes != null ? runtimes[runtimeId] : null;
|
|
const declaredFlag = runtimeEntry?.runtime?.harnessIsolationFlag ?? null;
|
|
return (typeof declaredFlag === 'string' && declaredFlag.length > 0) ? declaredFlag : null;
|
|
}
|
|
|
|
/**
|
|
* Conservative fallback resolution used when the #3045 sentinel is absent or
|
|
* stale: re-derive isolation from the registry CAPABILITY, gated by
|
|
* `workflow.use_worktrees` (config-schema key confirmed present in
|
|
* gsd-core/bin/shared/config-schema.manifest.json's validKeys, so it survives
|
|
* loadConfig's whitelist; read directly from the raw config.json here — same
|
|
* side-effect-free approach cmdConfigGet itself uses, not through loadConfig).
|
|
*
|
|
* MAJOR 2: when the runtime cannot be confidently determined (no GSD_RUNTIME
|
|
* override, no `runtime` key in config.json — the common case, since the
|
|
* project scaffold ships without one), this resolves to 'none' (inert)
|
|
* rather than guessing 'claude' and demanding Claude's flag on a host that
|
|
* may not even be Claude. Denying every dispatch on an undeterminable
|
|
* runtime would repeat the exact false-positive class the #3045 BLOCKER
|
|
* itself was — this is the fallback path only (the sentinel-fresh path above
|
|
* already carries the workflow's own confirmed decision + flag, so this
|
|
* degrades coverage only for dispatches that happen outside a GSD workflow
|
|
* run, e.g. a manual Agent() call before any sentinel has been written).
|
|
*/
|
|
function resolveRegistryIsolation(cwd, configPath) {
|
|
// #3582: self-heal the compiled runtime library BEFORE either require
|
|
// below — this is the only reaching path to both (resolveRegistryIsolation
|
|
// is the sole caller of each), so one call here covers both. Throws
|
|
// RuntimeBuildError on an unbuildable tree; the caller (resolveIsolationState)
|
|
// already wraps this whole function in try/catch and folds any error into
|
|
// its fail-closed `error` result — evaluateDispatch below distinguishes a
|
|
// RuntimeBuildError there so it surfaces this seam's actionable message
|
|
// instead of being misreported as an unreadable config.json (#3050 lesson).
|
|
ensureRuntimeBuild();
|
|
const { resolveRuntimeNameFromCandidates } = require('../gsd-core/bin/lib/runtime-name-policy.cjs');
|
|
const { runtimes } = require('../gsd-core/bin/lib/capability-registry.cjs');
|
|
|
|
const { runtimeId, confident } = resolveRuntimeIdentity(cwd, configPath, resolveRuntimeNameFromCandidates);
|
|
if (!confident) {
|
|
return { isolation: 'none', harnessFlag: null };
|
|
}
|
|
|
|
const runtimeEntry = runtimes != null ? runtimes[runtimeId] : null;
|
|
const declared = runtimeEntry?.runtime?.hostIntegration?.dispatch?.isolation ?? null;
|
|
let isolation = (typeof declared === 'string' && VALID_ISOLATION.has(declared)) ? declared : 'none';
|
|
|
|
let harnessFlag = null;
|
|
if (isolation === 'harness-worktree') {
|
|
harnessFlag = resolveHarnessFlag(runtimeId, runtimes);
|
|
if (harnessFlag === null) {
|
|
// A host claiming harness isolation with no declared flag gives this
|
|
// guard nothing to check for — degrade to 'none' rather than block on
|
|
// an unspecifiable requirement.
|
|
isolation = 'none';
|
|
}
|
|
}
|
|
|
|
if (isolation === 'harness-worktree') {
|
|
let useWorktrees = true;
|
|
try {
|
|
const raw = fs.readFileSync(configPath, 'utf-8');
|
|
const parsedCfg = JSON.parse(raw);
|
|
if (parsedCfg && typeof parsedCfg === 'object' && parsedCfg.workflow &&
|
|
typeof parsedCfg.workflow === 'object' && parsedCfg.workflow.use_worktrees === false) {
|
|
useWorktrees = false;
|
|
}
|
|
} catch {
|
|
// Unreadable config already propagated to the outer caller's catch
|
|
// before this point in practice (resolveRuntimeIdentity reads it
|
|
// first); tolerate defensively and keep the conservative (enforce)
|
|
// default rather than silently disabling the guard.
|
|
}
|
|
if (!useWorktrees) isolation = 'none';
|
|
}
|
|
|
|
return { isolation, harnessFlag };
|
|
}
|
|
|
|
/**
|
|
* Resolve this project's dispatch isolation mode, distinguishing three
|
|
* outcomes:
|
|
* - { gsdProject: false } — not a GSD project, inert
|
|
* - { gsdProject: true, error: <Error> } — cannot verify, DENY
|
|
* - { gsdProject: true, isolation, harnessFlag } — resolved cleanly
|
|
*
|
|
* `.planning/config.json` EXISTING (regardless of whether it can be read) is
|
|
* the GSD-project signal, mirroring gsd-workflow-guard.js /
|
|
* gsd-context-monitor.js. Any failure reading or parsing it, or requiring the
|
|
* sibling registry/policy modules, after that point means "GSD project
|
|
* present, isolation mode unknown" — folded into the DENY path rather than
|
|
* silently defaulting to a mode that happens to look safe.
|
|
*
|
|
* #3045 BLOCKER fix: prefer the workflow's own PERSISTED per-dispatch
|
|
* decision (the sentinel `record-dispatch-isolation` writes) over
|
|
* re-deriving a host CAPABILITY from the registry. The registry's
|
|
* harness-worktree entry means "this host CAN isolate", not "this dispatch
|
|
* SHOULD be isolated" — sequential ISOLATION=none legitimately happens even
|
|
* on a harness-worktree-capable host (project opt-out, per-plan submodule
|
|
* intersection, #683/#3060 base-check auto-degrade). A fresh sentinel is
|
|
* authoritative; an absent/stale one falls back to the conservative
|
|
* registry+config check via resolveRegistryIsolation.
|
|
*
|
|
* `clock` is injectable for the sentinel-staleness check (repo clock-seam
|
|
* convention); defaults to the real `Date`.
|
|
*
|
|
* `dispatchIds` (optional, `{plan, phase}`) is the identifiers extracted from
|
|
* THIS dispatch's own prompt/description text (#3045 SECURITY F2 —
|
|
* `extractDispatchIdentifiers` in `hooks/lib/isolation-sentinel.js`). When
|
|
* supplied and a fresh sentinel disagrees with it on a shared identifier, the
|
|
* sentinel is treated as NOT APPLICABLE to this dispatch (falls through to
|
|
* the conservative registry+config fallback below) rather than trusted —
|
|
* "a mismatch is 'no applicable sentinel', not an allow" (#3045 review).
|
|
*/
|
|
function resolveIsolationState(cwd, { clock = Date, dispatchIds = null } = {}) {
|
|
const configPath = path.join(cwd, '.planning', 'config.json');
|
|
let projectExists;
|
|
try {
|
|
fs.accessSync(configPath, fs.constants.F_OK);
|
|
projectExists = true;
|
|
} catch {
|
|
projectExists = false;
|
|
}
|
|
if (!projectExists) {
|
|
return { gsdProject: false, isolation: null, harnessFlag: null, error: null };
|
|
}
|
|
|
|
const sentinel = readSentinel(cwd, { clock });
|
|
if (sentinel.present && !sentinel.stale && sentinelAppliesToDispatch(sentinel, dispatchIds)) {
|
|
if (sentinel.isolation !== 'harness-worktree') {
|
|
return { gsdProject: true, isolation: sentinel.isolation, harnessFlag: null, error: null };
|
|
}
|
|
if (sentinel.harnessFlag) {
|
|
return { gsdProject: true, isolation: 'harness-worktree', harnessFlag: sentinel.harnessFlag, error: null };
|
|
}
|
|
// #3045 BLOCKER 2 fix: the sentinel already PROVED this dispatch requires
|
|
// isolation (it resolved harness-worktree) but carries no usable flag —
|
|
// this must DENY, not degrade to the registry's "not confident -> none"
|
|
// fallback. That degrade exists for the case where NOTHING has resolved
|
|
// isolation yet (the conservative fallback path below); reusing it here
|
|
// was the BLOCKER: a fresh sentinel asserting harness-worktree with no
|
|
// flag fell through to a registry lookup that, on the common "runtime not
|
|
// confidently determinable" case, silently returned isolation:'none' and
|
|
// ALLOWED the dispatch to run unisolated in the primary checkout — the
|
|
// exact failure this guard exists to prevent, and on the default-install
|
|
// path (no `runtime` key in gsd-core/templates/config.json), not a corner
|
|
// case. With the #3045 CORE REDESIGN, `dispatch-isolation` always resolves
|
|
// and records `harnessFlag` together with `isolation` in one atomic write
|
|
// whenever isolation is 'harness-worktree' (routeDispatchIsolation
|
|
// degrades to 'none' itself when no flag is declared) — so a fresh
|
|
// sentinel with isolation:'harness-worktree' and no flag should not occur
|
|
// in practice. This branch is defense-in-depth for a sentinel written by
|
|
// an older gsd-tools.cjs, a hand-crafted/corrupted-in-a-*valid*-way
|
|
// sentinel, or any other path that reaches this state; it MUST deny.
|
|
return {
|
|
gsdProject: true,
|
|
isolation: null,
|
|
harnessFlag: null,
|
|
error: new Error(
|
|
'dispatch-isolation sentinel resolved "harness-worktree" but recorded no harness_flag — ' +
|
|
'cannot verify what parameter the dispatch must carry.'
|
|
),
|
|
};
|
|
}
|
|
|
|
// Sentinel absent, stale, or does not apply to this dispatch (F2 mismatch):
|
|
// conservative fallback (#3045 finding — must still cover fail-closed case
|
|
// (a): a project that opted out of worktrees entirely via
|
|
// workflow.use_worktrees).
|
|
try {
|
|
const { isolation, harnessFlag } = resolveRegistryIsolation(cwd, configPath);
|
|
return { gsdProject: true, isolation, harnessFlag, error: null };
|
|
} catch (err) {
|
|
return { gsdProject: true, isolation: null, harnessFlag: null, error: err };
|
|
}
|
|
}
|
|
|
|
/**
|
|
* Process one PreToolUse payload (already JSON-parsed) and return the
|
|
* decision without touching stdin/stdout/process.exit — the exported,
|
|
* directly-testable core of this hook's logic (#3045 MAJOR: "the clock seam
|
|
* is dead code" fix). The stdin-driven script below is now a thin adapter
|
|
* over this function so tests can `require()` it and inject a `clock`
|
|
* (`{now(): number}`) directly per the repo's clock-seam convention, instead
|
|
* of racing real `Date.now()` across a spawned subprocess boundary.
|
|
*
|
|
* Returns `{ action: 'allow' } | { action: 'block', reason: string }`.
|
|
*/
|
|
function evaluateDispatch(data, { clock = Date } = {}) {
|
|
if (!data || typeof data !== 'object') return { action: 'allow' };
|
|
// #3045 MAJOR 1: accept both subagent-dispatch tool names. hooks.json's
|
|
// matcher is "Agent|Task" (mirroring the repo's own PostToolUse
|
|
// precedent) so this must match both, or it is silently inert on any
|
|
// host/version whose subagent tool is named "Task".
|
|
if (data.tool_name !== 'Agent' && data.tool_name !== 'Task') return { action: 'allow' };
|
|
|
|
const toolInput = (data.tool_input && typeof data.tool_input === 'object') ? data.tool_input : {};
|
|
const subagentType = toolInput.subagent_type;
|
|
if (typeof subagentType !== 'string' || !EXECUTOR_SUBAGENT_TYPES.has(subagentType)) {
|
|
return { action: 'allow' };
|
|
}
|
|
|
|
const cwd = data.cwd || process.cwd();
|
|
// #3045 SECURITY F2: best-effort plan/phase extraction from this
|
|
// dispatch's own description text, so a fresh sentinel that disagrees
|
|
// with THIS dispatch is treated as inapplicable rather than trusted.
|
|
const dispatchIds = extractDispatchIdentifiers(toolInput.description);
|
|
const state = resolveIsolationState(cwd, { clock, dispatchIds });
|
|
|
|
if (!state.gsdProject) return { action: 'allow' };
|
|
|
|
if (state.error) {
|
|
// #3582: a missing/unbuildable compiled runtime library (RuntimeBuildError,
|
|
// thrown by ensureRuntimeBuild in resolveRegistryIsolation) is a DIFFERENT,
|
|
// actionable failure from an unreadable/unparsable config.json — surface
|
|
// its own message instead of misreporting it as the generic
|
|
// "could not read or resolve ... configuration" text (the exact #3050
|
|
// misreport this issue exists to fix). Both cases still fail closed
|
|
// (block); only the message differs.
|
|
const isBuildFailure = state.error instanceof RuntimeBuildError;
|
|
const reason = isBuildFailure
|
|
? `Agent isolation guard: cannot resolve this project's dispatch-isolation ` +
|
|
`configuration because the GSD runtime library failed to self-build. ` +
|
|
`${state.error.message} Refusing to dispatch subagent_type="${subagentType}" until ` +
|
|
`the runtime library is built — a guard that cannot verify must not answer "safe" ` +
|
|
`(#3050).`
|
|
: `Agent isolation guard: could not read or resolve this project's dispatch-isolation ` +
|
|
`configuration ('.planning/config.json' under '${cwd}'). Refusing to dispatch ` +
|
|
`subagent_type="${subagentType}" without being able to verify whether isolation is ` +
|
|
`required — a guard that cannot verify must not answer "safe" (#3050). Retry once the ` +
|
|
`project configuration is readable.`;
|
|
const reasonCode = isBuildFailure ? REASON_CODE.RUNTIME_BUILD_FAILED : REASON_CODE.CONFIG_UNREADABLE;
|
|
return { action: 'block', reason, reasonCode };
|
|
}
|
|
|
|
if (state.isolation !== 'harness-worktree') return { action: 'allow' };
|
|
|
|
const parsed = parseHarnessFlag(state.harnessFlag);
|
|
if (!parsed) return { action: 'allow' };
|
|
|
|
if (toolInput[parsed.param] === parsed.value) return { action: 'allow' };
|
|
|
|
const reason =
|
|
`Agent isolation guard: this project's dispatch isolation resolves to "harness-worktree", ` +
|
|
`but the Agent() dispatch for subagent_type="${subagentType}" is missing ` +
|
|
`${parsed.param}="${parsed.value}". Add ${parsed.param}="${parsed.value}" to the Agent() ` +
|
|
`call so the executor runs in an isolated worktree instead of the primary checkout ` +
|
|
`(gsd-core/workflows/execute-phase/steps/executor-isolation-dispatch.md).`;
|
|
return { action: 'block', reason, reasonCode: REASON_CODE.HARNESS_FLAG_MISSING };
|
|
}
|
|
|
|
/* istanbul ignore next -- stdin adapter, exercised via spawnSync in tests */
|
|
function main() {
|
|
let input = '';
|
|
const stdinTimeout = setTimeout(() => allow(undefined), 3000);
|
|
process.stdin.setEncoding('utf8');
|
|
process.stdin.on('data', (chunk) => { input += chunk; });
|
|
process.stdin.on('end', () => {
|
|
clearTimeout(stdinTimeout);
|
|
try {
|
|
const data = JSON.parse(input);
|
|
const decision = evaluateDispatch(data);
|
|
if (decision.action === 'block') {
|
|
const out = { decision: 'block', reason: decision.reason, reason_code: decision.reasonCode };
|
|
// Kimi feeds stderr (not stdout) back to the model on exit 2.
|
|
deny(out, decision.reason);
|
|
}
|
|
allow(undefined);
|
|
} catch {
|
|
// Silent fail — never block valid tool calls due to hook errors
|
|
// (malformed payload, etc.). This is distinct from resolveIsolationState's
|
|
// internal error handling, which DOES deny — this outer catch only
|
|
// covers payload parsing before applicability could even be determined.
|
|
// ON_CRASH is declared ALLOW at module top: this preserves today's
|
|
// exit(0) fail-open behavior exactly (#3911).
|
|
crash(ON_CRASH, undefined);
|
|
}
|
|
});
|
|
}
|
|
|
|
if (require.main === module) {
|
|
main();
|
|
}
|
|
|
|
module.exports = {
|
|
evaluateDispatch,
|
|
resolveIsolationState,
|
|
resolveRuntimeIdentity,
|
|
resolveHarnessFlag,
|
|
resolveRegistryIsolation,
|
|
parseHarnessFlag,
|
|
_setInstallRuntimeMarkerForTests,
|
|
};
|